1. Academic Validation
  2. Full Thickness Macular Hole Closure after Exchanging Silicone-Oil Tamponade with C(3)F(8) without Posturing

Full Thickness Macular Hole Closure after Exchanging Silicone-Oil Tamponade with C(3)F(8) without Posturing

  • Case Rep Ophthalmol. 2011 May;2(2):166-9. doi: 10.1159/000327695.
Tina Xirou 1 Vasiliki Xirou George Mangouritsas Elias Feretis Stamatina A Kabanarou
Affiliations

Affiliation

  • 1 Retina Department, Hellenic Red Cross General Hospital, Athens, Greece.
Abstract

Purpose: To report a case of macular hole closure after the exchange of a silicone-oil tamponade with gas C(3)F(8) 14%.

Method: A 64-year-old female patient with a stage IV macular hole underwent a three-port pars-plana vitrectomy and internal limiting membrane peeling. Due to the patient's chronic illness (respiratory problems), a silicone-oil tamponade was preferred. However, the macula hole was still flat opened four months postoperatively. Therefore, the patient underwent an exchange of silicone oil with gas C(3)F(8) 14%. No face-down position was advised postoperatively due to her health problems.

Results: Macular hole closure was confirmed with optical coherence tomography six weeks after exchanging the silicone oil with gas.

Conclusions: Macular hole surgery using a silicone-oil tamponade has been proposed as treatment of choice for patients unable to posture. In our case, the use of a long-acting gas (C(3)F(8) 14%), even without posturing, proved to be more effective.

Keywords

Idiopathic macular hole; Internal limiting membrane peeling; Long-acting gas; Silicone-oil tamponade; Vitrectomy.

Figures