1. Academic Validation
  2. Method development and validation for total haloxyfop analysis in infant formulas and related ingredient matrices using liquid chromatography-tandem mass spectrometry

Method development and validation for total haloxyfop analysis in infant formulas and related ingredient matrices using liquid chromatography-tandem mass spectrometry

  • Anal Bioanal Chem. 2018 Sep;410(22):5521-5528. doi: 10.1007/s00216-018-1085-8.
Urairat Koesukwiwat 1 Lukas Vaclavik 2 Katerina Mastovska 3
Affiliations

Affiliations

  • 1 Covance (Asia) Pte. Ltd., Covance Food Solutions, The Synergy, International Business Park, Singapore, 609917, Singapore.
  • 2 Covance Laboratories Inc., Covance Food Solutions, Otley Road, Harrogate, North Yorkshire, HG3 1PY, UK.
  • 3 Covance Laboratories Inc., Covance Food Solutions, 3301 Kinsman Blvd., Madison, WI, 53704, USA. katerina.mastovska@covance.com.
Abstract

According to the European Commission directive 2006/141/EC, haloxyfop residue levels should not exceed 0.003 mg/kg in ready-to-feed infant formula, and the residue definition includes sum of haloxyfop, its esters, salts, and conjugates expressed as haloxyfop. A simple method for total haloxyfop analysis in infant formula and related ingredient matrices was developed and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The sample preparation consisted of an alkaline hydrolysis with methanolic sodium hydroxide to release haloxyfop (parent acid) from its bound forms prior to the extraction with acetonitrile. A mixture of magnesium sulfate (MgSO4) and sodium chloride (NaCl) (4:1, w/w) was added to the extract to induce phase separation and force the analyte into the upper acetonitrile-methanol layer and then a 1-mL aliquot was subsequently cleaned up by dispersive solid phase extraction with 150 mg of MgSO4 and 50 mg of octadecyl (C18) sorbent. The analytical procedure was developed and carefully optimized to enable low-level, total haloxyfop analysis in a variety of challenging matrices, including infant formulas and their important high-carbohydrate, high-protein, high-fat, and emulsifier ingredients. The final method was validated in two different laboratories by fortifying samples with haloxyfop and haloxyfop-methyl, which was used as a model compound simulating bound forms of the analyte. Mean recoveries of haloxyfop across all fortification levels and evaluated matrices ranged between 92.2 and 114% with repeatability, within-lab reproducibility, and reproducibility RSDs ≤ 14%. Based on the validation results, this method was capable to convert the haloxyfop ester into the parent acid in a wide range of sample types and to reliably identify and quantify total haloxyfop at the target 0.003 mg/kg level in infant formulas (both powdered and ready-to-feed liquid forms). Graphical abstract LC-MS/MS-based workflow for the determination of the total haloxyfop in infant formula and related ingredients.

Keywords

Alkaline hydrolysis; Infant formula; Liquid chromatography-tandem mass spectrometry; Pesticides; Phenoxy acid herbicides; QuEChERS.

Figures
Products