1. Academic Validation
  2. Analytical quality by design development of an ecologically acceptable enantioselective HPLC method for timolol maleate enantiomeric purity testing on ovomucoid chiral stationary phase

Analytical quality by design development of an ecologically acceptable enantioselective HPLC method for timolol maleate enantiomeric purity testing on ovomucoid chiral stationary phase

  • J Pharm Biomed Anal. 2020 Feb 20;180:113034. doi: 10.1016/j.jpba.2019.113034.
Marija Mitrović 1 Ana Protić 2 Anđelija Malenović 2 Biljana Otašević 2 Mira Zečević 2
Affiliations

Affiliations

  • 1 University of Belgrade, Faculty of Pharmacy, Department of Drug Analysis, Vojvode Stepe 450, Belgrade, Serbia. Electronic address: marija.mitrovic@pharmacy.bg.ac.rs.
  • 2 University of Belgrade, Faculty of Pharmacy, Department of Drug Analysis, Vojvode Stepe 450, Belgrade, Serbia.
Abstract

Official method in Ph. Eur. for evaluation of timolol enantiomeric purity is normal-phase high performance liquid chromatography (NP-HPLC) method. Compared to other HPLC modes, NP is depicted as quite expensive with high consumption of organic solvents which leads to chronic exposure of analysts to toxic and carcinogenic effects. In order to overcome above-mentioned drawbacks, the aim of this study was to develop new method with better eco-friendly features. This was enabled by using protein type Chiral Stationary Phase (CSP) in reversed-phase mode that required up to 10 % (v/v) of organic solvent. Therefore, an enantioselective HPLC method was developed and validated for quantification of (S)-timolol and its chiral impurity, (R)-isomer. Optimized separation conditions on ovomucoid column were set using Analytical Quality by Design (AQbD) approach in method development. Optimization step was performed following the Box-Behnken experimental plan and the influence of three critical method parameters (CMPs) towards enantioseparation of the above-mentioned peak pair was examined. CMPs included variation of acetonitrile content in the mobile phase (5-10 %, v/v), pH value of the aqueous phase (6.0-7.0) and ammonium chloride concentration in the aqueous part of the mobile phase (10-30 mmol L-1). The most relevant critical method attributes (CMAs) in this case were the separation criterion between studied critical pair and retention factor of the second eluting peak, (S)-timolol. Qualitative Design Space (DS) was defined by Monte Carlo simulations providing adequate assurance of method's qualitative robustness (π = 95 %). The selected working point situated in the middle of the DS was characterized by following combination of CMPs: acetonitrile content in the mobile phase 7 % (v/v), pH value of the aqueous phase 6.8 and concentration of ammonium chloride in aqueous phase 14 mmol L-1. In the next step, the quantitative robustness was tested by Plackett-Burman experimental design. The validation studies confirmed adequacy of the proposed method for its intended purpose. Finally, Analytical Eco-Scale metric tool was applied to confirm that developed method represents excellent green analytical method compared to the official one.

Keywords

Analytical quality by design; Enantiomeric purity testing; Method validation; Ovomucoid CSP; Timolol enantiomers.

Figures