1. Academic Validation
  2. Can in vitro/in silico tools improve colonic concentration estimations for oral extended-release formulations? A case study with upadacitinib

Can in vitro/in silico tools improve colonic concentration estimations for oral extended-release formulations? A case study with upadacitinib

  • J Control Release. 2024 Apr 24:370:182-194. doi: 10.1016/j.jconrel.2024.04.024.
Alessia Favaron 1 Bart Hens 2 Maiara Camotti Montanha 3 Mark McAllister 3 Irena Tomaszewska 3 Shaimaa Moustafa 3 Marília Alvarenga de Oliveira 3 Abdul W Basit 4 Mine Orlu 5
Affiliations

Affiliations

  • 1 UCL School of Pharmacy, University College London, London WC1N 1AX, UK.
  • 2 Drug Product Design, Pfizer, Sandwich, Kent CT13 9NJ, United Kingdom. Electronic address: bart.hens@pfizer.com.
  • 3 Drug Product Design, Pfizer, Sandwich, Kent CT13 9NJ, United Kingdom.
  • 4 UCL School of Pharmacy, University College London, London WC1N 1AX, UK.. Electronic address: a.basit@ucl.ac.uk.
  • 5 UCL School of Pharmacy, University College London, London WC1N 1AX, UK.. Electronic address: m.orlu@ucl.ac.uk.
Abstract

Upadacitinib, classified as a highly soluble drug, is commercially marketed as RINVOQ®, a modified-release formulation incorporating hydroxypropyl methylcellulose as a matrix system to target extended release throughout the gastrointestinal (GI) tract. Our study aimed to explore how drug release will occur throughout the GI tract using a plethora of in vitro and in silico tools. We built a Physiologically-Based Pharmacokinetic (PBPK) model in GastroPlus™ to predict the systemic concentrations of the drug when administered using in vitro dissolution profiles as input to drive luminal dissolution. A series of in vitro dissolution experiments were gathered using the USP Apparatus I, III and IV in presence of biorelevant media, simulating both fasted and fed state conditions. A key outcome from the current study was to establish an in vitro-in vivo correlation (IVIVC) between (i) the dissolution profiles obtained from the USP I, III and IV methods and (ii) the fraction absorbed of drug as deconvoluted from the plasma concentration-time profile of the drug. When linking the fraction dissolved as measured in the USP IV model, a Level A IVIVC was established. Moreover, when using the different dissolution profiles as input for PBPK modeling, it was also observed that predictions for plasma Cmax and AUC were most accurate for USP IV compared to the Other models (based on predicted versus observed ratios). Furthermore, the PBPK model has the utility to extract the predicted concentrations at the level of the colon which can be of utmost interest when working with specific in vitro assays.

Keywords

Colonic targeting; Dissolution; Modeling; Oral drug delivery; Rinvoq; Upadacitinib.

Figures
Products