1. Academic Validation
  2. Two dimensional chromatography mass spectrometry: Quantitation of chiral shifts in metabolism of propranolol in bioanalysis

Two dimensional chromatography mass spectrometry: Quantitation of chiral shifts in metabolism of propranolol in bioanalysis

  • J Chromatogr A. 2020 Apr 26:1617:460828. doi: 10.1016/j.chroma.2019.460828.
Lukas C Harps 1 Sonja Schipperges 2 Felix Bredendiek 1 Bernhard Wuest 2 Andreas Borowiak 2 Maria Kristina Parr 3
Affiliations

Affiliations

  • 1 Freie Universitaet Berlin, Institute of Pharmacy - Pharmaceutical Analysis, Königin-Luise-Str. 2+4, 14195 Berlin, Germany.
  • 2 Agilent Technologies R&D and Marketing GmbH and Co. KG, Waldbronn, Germany.
  • 3 Freie Universitaet Berlin, Institute of Pharmacy - Pharmaceutical Analysis, Königin-Luise-Str. 2+4, 14195 Berlin, Germany. Electronic address: maria.parr@fu-berlin.de.
Abstract

In this study a heart-cutting 2D-LC method was successfully developed and optimized in order to discriminate and quantitate (S)-propranolol, (R)-propranolol, and its hydroxy metabolites, namely the isomeric (S)-4'‑hydroxy propranolol, (R)-4'‑hydroxy propranolol, (S)-5'‑hydroxy propranolol, (R)-5'‑hydroxy propranolol, (S)-7'-hydroxy propranolol, and (R)-7'‑hydroxy propranolol in one chromatographic run. Thereby, experiments investigating chiral discrimination in ring hydroxylation of propranolol were made feasible. Analysis of human urine samples after administration of a single oral dose of 40 mg of propranolol clearly revealed considerable chiral shifts in propranolol and its 4'-, 5'-, and 7'-hydroxy metabolites. Furthermore, the excretion rates of the individual (S)- and (R)-enantiomers were continuously monitored over 24 h post administration. Studies were performed utilizing a 2D-LC system hyphenated to a triple quadrupole mass spectrometer. The chromatographic system was endued with a reversed phase column (phenyl-hexyl) in first dimension and a teicoplanin based chiral column in second dimension. The method was basically validated and successfully evaluated as robust. Calibration was performed achieving accuracy between 80% and 120%. Maximal excretion rates of (S)-propranolol, (R)-propranolol, (S)-4'‑hydroxy propranolol, (R)-4'‑hydroxy propranolol, (S)-5'‑hydroxy propranolol, (R)-5'‑hydroxy propranolol, and (R)-7'‑hydroxy propranolol were 237 ng/min, 281 ng/min, 4 ng/min, 4 ng/min, 1 ng/min, 9 ng/min, and 3 ng/min, respectively.

Keywords

2D-LC-QQQ-MS/MS; Beta-blocker; Bioanalysis; Enantiomers; Propranolol; Two dimensional chromatography; Urinary excretion.

Figures
Products