1. Academic Validation
  2. Characterization of the novel P-selectin inhibitor PSI-697 [2-(4-chlorobenzyl)-3-hydroxy-7,8,9,10-tetrahydrobenzo[h] quinoline-4-carboxylic acid] in vitro and in rodent models of vascular inflammation and thrombosis

Characterization of the novel P-selectin inhibitor PSI-697 [2-(4-chlorobenzyl)-3-hydroxy-7,8,9,10-tetrahydrobenzo[h] quinoline-4-carboxylic acid] in vitro and in rodent models of vascular inflammation and thrombosis

  • J Pharmacol Exp Ther. 2008 Feb;324(2):497-506. doi: 10.1124/jpet.107.128124.
Patricia W Bedard 1 Valerie Clerin Natalia Sushkova Boris Tchernychev Thomas Antrilli Christine Resmini James C Keith Jr James K Hennan Neelu Kaila Silvano Debernardo Kristin Janz Qin Wang David L Crandall Robert G Schaub Gray D Shaw Laura L Carter
Affiliations

Affiliation

  • 1 Wyeth Research, 200 Cambridge Park Drive, Cambridge, MA 02140, USA. pbedard@wyeth.com
Abstract

P-selectin plays a significant and well documented role in vascular disease by mediating leukocyte and platelet rolling and adhesion. This study characterizes the in vitro activity, pharmacokinetic properties, and the anti-inflammatory and antithrombotic efficacy of the orally active P-selectin small-molecule antagonist PSI-697 [2-(4-chlorobenzyl)-3-hydroxy-7,8,9,10-tetrahydrobenzo[h] quinoline-4-carboxylic acid; molecular mass, 367.83]. Biacore and cell-based assays were used to demonstrate the ability of PSI-697 to dose dependently inhibit the binding of human P-selectin to human P-selectin glycoprotein ligand-1, inhibiting 50% of binding at 50 to 125 microM. The pharmacokinetics of PSI-697 in rats were characterized by low clearance, short half-life, low volume of distribution, and moderate apparent oral bioavailability. A surgical inflammation model, using exteriorized rat cremaster venules, demonstrated that PSI-697 (50 mg/kg p.o.) significantly reduced the number of rolling leukocytes by 39% (P < 0.05) versus vehicle control. In a rat venous thrombosis model, PSI-697 (100 mg/kg p.o.) reduced thrombus weight by 18% (P < 0.05) relative to vehicle, without prolonging bleeding time. Finally, in a rat carotid injury model, PSI-697 (30 or 15 mg/kg p.o.) administered 1 h before arterial injury and once daily thereafter for 13 days resulted in dose-dependent decreases in intima/media ratios of 40.2% (P = 0.025) and 25.7% (P = 0.002) compared with vehicle controls. These data demonstrate the activity of PSI-697 in vitro and after oral administration in animal models of both arterial and venous injury and support the clinical evaluation of this novel antagonist of P-selectin in atherothrombotic and venous thrombotic indications.

Figures
Products
  • Cat. No.
    Product Name
    Description
    Target
    Research Area
  • HY-15526
    99.73%, P-selectin Inhibitor