  2. Development and validation of an ultra-performance liquid chromatography-tandem mass spectrometry method to quantify the small molecule inhibitors adagrasib, alectinib, brigatinib, capmatinib, crizotinib, lorlatinib, selpercatinib, and sotorasib in human plasma

Development and validation of an ultra-performance liquid chromatography-tandem mass spectrometry method to quantify the small molecule inhibitors adagrasib, alectinib, brigatinib, capmatinib, crizotinib, lorlatinib, selpercatinib, and sotorasib in human plasma

  • Biomed Chromatogr. 2024 Oct;38(10):e5986. doi: 10.1002/bmc.5986.
Esther M Hollander 1 Nachel M C Zimmerman 1 Berber Piet 2 Michel M van den Heuvel 2 David M Burger 1 Lindsey H M Te Brake 1 Rob Ter Heine 1
Affiliations

Affiliations

  • 1 Department of Pharmacy and Research Institute for Medical Innovation, Radboud University Medical Center, Nijmegen, The Netherlands.
  • 2 Department of Pulmonology, Radboud University Medical Center, Nijmegen, The Netherlands.
Abstract

Small molecule inhibitors (SMIs) are increasingly being used in the treatment of non-small cell lung Cancer. To support pharmacokinetic research and clinical treatment monitoring, our aim was to develop and validate an ultra-performance liquid chromatography-mass spectrometry (UPLC-MS/MS) assay for quantification of eight SMIs: adagrasib, alectinib, brigatinib, capmatinib, crizotinib, lorlatinib, selpercatinib, and sotorasib. Development of the UPLC-MS/MS assay was done by trying different columns and eluents to optimize peak shape. The assay was validated based on guidelines of the European Medicines Agency. Chromatographic separation was performed with a gradient elution using ammonium formate in water and methanol. Detection was performed using a triple quadrupole tandem mass spectrometer with electrospray ionization. Validation was performed in a range of 10-2500 μg/L for lorlatinib, 25-6250 μg/L for alectinib and crizotinib, 25-10,000 μg/L for capmatinib and selpercatinib, 50-12,500 μg/L for brigatinib, and 100-25,000 μg/L for adagrasib and sotorasib. Imprecision was <8.88% and inaccuracy was <12.5% for all compounds. Seven out of eight compounds were stable for 96 h at room temperature. Sotorasib was stable for 8 h at room temperature. A sensitive and reliable method has been developed to quantify eight SMIs with a single assay, enhancing efficacy and safety of targeted therapies.

Keywords

mass spectrometry; non‐small cell lung cancer; small molecule inhibitors; targeted therapy.